Zu Hause > produits > Drucktransmitter für die Industrie >
New Endress Hauser PMC71B Pressure Measurement Sensor Absolute Gauge Pressure Transmitter With 4-20ma Hart Output

New Endress Hauser PMC71B Pressure Measurement Sensor Absolute Gauge Pressure Transmitter With 4-20ma Hart Output

Endress Hauser PMC71B pressure sensor

absolute gauge pressure transmitter

4-20mA HART output pressure sensor

Herkunftsort:

China

Markenname:

E+H

Modellnummer:

PMC71B

Plaudern Sie Jetzt
Bitte um ein Angebot
Einzelheiten zum Produkt
Vakuumresistenz:
10 Mbar (0,15 psi)
Schutzbewertung:
IP67
Drucktyp:
Druckdruck
Messbereich:
0-1000 Stange
Ansprechzeit:
≤ 5 ms
Wohnmaterial:
Aluminium
Elektrische Verbindung:
M12x1
Montage:
Direkt oder fern
Prozessanbindung:
- Das ist ein halber Zoll.
Genauigkeit:
± 0,1% fs
Leistung:
Elektrisch
Montagemethode:
DIN -Schiene oder Wandhalterung
Montageart:
Gewinde
Drucktyp:
Absolute, versiegelte Messung
Hervorheben:

Endress Hauser PMC71B pressure sensor

,

absolute gauge pressure transmitter

,

4-20mA HART output pressure sensor

Zahlungs- und Versandbedingungen
Min Bestellmenge
1 PC
Preis
USD 400
Lieferzeit
7-14 Tage
Zahlungsbedingungen
T/T
Versorgungsmaterial-Fähigkeit
100 pc
Beschreibung des Produkts

What Is the Cerabar PMC71B?

  • The Cerabar PMC71B is a smart digital pressure transmitter from Endress+Hauser.
  • It uses a dry, oil-free ceramic measuring cell to measure pressure.
  • It’s part of the “Cerabar” family — designed for robust and reliable pressure measurement, especially in challenging process environments.

 

Key Specifications

Here are some of its main technical characteristics:

Parameter

Value / Details

Pressure Range

100 mbar … 40 bar (≈ 1.5 psi … 600 psi)

Accuracy

Standard: up to ± 0.05%
Platinum version: up to ± 0.025%

Process Temperature

–40 °C … +150 °C (–40 °F … +302 °F)

Wetted (Process) Materials

Ceraphire ceramic; seal materials: FKM, EPDM, HNBR, Perlast, Kalrez, Chemraz

Membrane / Sensing Element

Ceramic membrane

Power / Communication

Supports 4-20 mA output; also supports digital communication (HART, etc.) through configuration

 

Special Features & Advantages

  • Vacuum Resistance: The PMC71B is fully vacuum resistant up to +150 °C, making it suitable for vacuum applications.
  • High Purity & Durability: The ceramic measuring cell is very resistant to corrosive or abrasive media, offering long-term stability.
  • Membrane Breakage Detection: It has built-in diagnostics to detect if the ceramic diaphragm is damaged, improving safety.
  • Heartbeat Technology: This enables continuous self-diagnostics and monitoring, so you can detect anomalies like loop characteristic changes while the device is running.
  • Remote Configuration: The device can be configured and controlled wirelessly via a secure Bluetooth connection using the SmartBlue app.
  • User-Friendly Software: Setup, proof tests, and verification are streamlined via intuitive wizards — simplifies commissioning and maintenance.
  • SIL Capability: It supports safety integrity levels (SIL) and guided proof testing, helping reduce systematic failures.
  •  

Typical Applications

  • Vacuum Systems: Because of its vacuum resistance and ceramic cell, it's ideal for vacuum pressure measurement.
  • Aggressive Media: Suitable for corrosive or abrasive fluids/gases due to the ceramic membrane.
  • Process Monitoring: In critical processes where you need to continuously monitor the health of the transmitter (via Heartbeat Technology).
  • Hygienic / High-Purity: Where contamination or leakage of process fluid must be avoided.

 

Limitations & Considerations

  • Ceramic sensors can be more expensive than metallic ones, so cost may be higher, especially for simple, non-aggressive applications.
  • While robust, it needs to be correctly configured (range, output, diagnostics) to get full value from features like self-verification.
  • Bluetooth setup is very convenient, but in some highly restricted or classified zones, remote wireless configuration may not be desirable — check your process safety policy.

 

Parameter

Specification

Pressure Range

100 mbar … 40 bar

Accuracy

Standard: ± 0.05% Platinum: ± 0.025%

Process Temperature

–40 °C … +150 °C

Ambient Temperature

–40 °C … +85 °C (depends on display variant)

Overpressure Limit

up to 60 bar (depending on version)

Measuring Cell / Sensor

Dry, oil-free ceramic (Ceraphire)

Wetted Materials

Ceraphire; Seals: FKM, EPDM, HNBR, Perlast, Kalrez, Chemraz

Process Connection

Thread: G1/2 … G2, R1/2, NPT, etc.; Flange: DN25 … DN80

Output / Communication

4–20 mA + HART; optional Bluetooth (SmartBlue); PROFINET APL

Power Supply

10.5 … 35 V DC (non-Ex)

Diagnostics / Safety Features

Heartbeat Technology for self-diagnostics, membrane breakage detection

Certifications / Approvals

ATEX, IECEx, CSA, SIL, EN 10204-3.1

Long-Term Stability

0.05% of URL / year

Response Time

HART cyclic: ~160 ms; acyclic: ~330 ms (typical)

Vacuum Capability

Fully vacuum resistant (0 mbar abs)

 

Senden Sie Ihre Anfrage direkt an uns

Datenschutzrichtlinie China gut Qualität Drucktransmitter für die Industrie Lieferant. Urheberrecht © 2024-2025 Xi'an Xiyi Central Control Technology Co., Ltd. - Alle. Alle Rechte vorbehalten.